0.22 um nylon syringe filters
0.45 um nylon syringe filters
5.0 um nylon syringe filters
nylon syringe filters
0.22um Nylon Syringe Filters
0.45 PVDF sterile Syringe Filter for Lab
0.22 PVDF sterile Syringe Filter for HPLC
Nylon sterile Syringe Filters
0.45 Nylon sterile Syringe Filters
0.22 Nylon sterile Syringe Filters

Nylon Syringe Filters

Filter Media: Nylon
Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Housing: Medical PP
Pore Size: 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm


Select:  Nylon Syringe Filters,   Disposable Nylon Syringe Filters,   Sterile Nylon Syringe Filters

Description of Nylon Syringe Filters

1. Nylon Syringe Filters
Good high temperature resistance, can withstand 121 saturated steam autoclave sterilization for 20 minutes, the highest working temperature is 60 degrees Celsius, good chemical stability, can withstand dilute acids, alcohols, esters, oils, hydrocarbons, halogenated hydrocarbons and organic oxides and many other organic and inorganic compounds. Nylon micron syringe filters is usually used for clarification and sterilization of water and organic solutions, while luer lock glass fiber syringe filters is used for coarse filtration processes such as prefiltration.

Features

Hydrophilic syringe filter
•Resistant to a range of organic solvents
•Comprehensive pore size from 0.1μm to 10μm
•Luer Lock inlet tip makes secures connections & avoid blowoff

Advantages of Nylon Syringe Filter 0.22/0.45

•Nylon production filter
•Imported high-quality membrane
•Medical grade PP material shell
•ISO9001, CE double approved, COA test report available
•Rugged construction to bear autoclave at 121°C at 1 bar for 20 Minutes/EO/Gamma

Applications

•Biological samples preparation
•Suitable for use with high pH samples
•HPLC samples containing low solid content-filtration will improve column life
Technical Data
Filter Media Nylon
Diameter 4mm 13mm 25mm 33mm 50mm
Housing Medical PP Medical PP Medical PP Medical PP Medical PP
Pore Size 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm
Filtration Area 0.2cm2 1.3cm2 4.9cm2 8.5cm2 19.8cm2
Maximum Pressure 5.2bar 5.2bar 5.2bar 5.2bar 5.2bar
Process Volume 2mL 10mL 100mL 200mL 5000mL
Pre-filter 1μm GF or PP 1μm GF or PP 1μm GF or PP 1μm GF or PP 1μm GF or PP
Hold-up Volume < 10μL < 50μL < 100μL < 200μL < 350μL
Inlet Female Luer Lock Female Luer Lock Female Luer Lock Female Luer Lock Stepped barb
Outlet Male luer slip Male luer slip Male luer slip Male luer slip Stepped barb
Operate temperature 60°C
 
Ordering Information
Item Code Pore Size(μm) Diameter(mm) Sterile Pre-filter Quantity/pk
SLNY1322N 0.22 13 No No 100pcs
SLNY1345N 0.45 13 No No 100pcs
SLNY1322NP 0.22 13 No PP 100pcs
SLNY1345NP 0.45 13 No PP 100pcs
SLNY1322NG 0.22 13 No GF 100pcs
SLNY1345NG 0.45 13 No GF 100pcs
SLNY2522N 0.22 25 No No 100pcs
SLNY2545N 0.45 25 No No 100pcs
SLNY2522NP 0.22 25 No PP 100pcs
SLNY2545NP 0.45 25 No PP 100pcs
SLNY2522NG 0.22 25 No GF 100pcs
SLNY2545NG 0.45 25 No GF 100pcs
Download All Ordering Information
2. Disposable Nylon Syringe Filters

Description of 0.45 um Nylon Syringe Filter

Hawach filter is with the membrane made from the domestic quality supplier. Syringe filters with pore size of 0.22μm are green, and syringe filter with pore size of 0.45μm is white. 0.45 um Nylon syringe filter is widely used in laboratories. Nylon filter membrane is a general-purpose filter membrane, so the Nylon syringe filter suitable for filtering most sample solutions and solvents. nylon syringe filter 13mm is ideal for filtering small samples of HPLC and GC. For organic solvent filtration, such as HPLC mobile phase particle removal filtration, nylon syringe filter is more economical and practical than luer lock filter.https://www.hawachfilters.com/hydrophobic-syringe-filters/

Features of Nylon Syringe Filters 13mm

•Color-coded design make nylon syringe filter easier for identification
•Divided into nylon syringe filters 13mm and 25mm
Hydrophilic syringe filter

Advantages

•Natural hydrophilicity
•No need to infiltrate before use
•Resistant to alkali and organic liquids

Applications
•Nylon syringe filter 13mm is ideal for food analysis
Technical Data
Filter Media Hydrophilic Nylon
Pore Size 0.22μm 0.45μm
Diameter 13mm 25mm
Housing Medical PP Medical PP
Bubble Point 0.31Mpa 0.19Mpa
Filtration Area 1.0cm2 4.3cm2
Maximum Operating Pressure 6.2bar 6.2bar
Process Volume 10mL 100mL
Hold-up Volume < 25μL < 100μL
Inlet Female Luer Lock Female Luer Lock
Outlet Male Luer Unlock Male Luer Unlock
Flow Direction Flow should enter from the inlet
Maximum Operating Temperature 60°C
Sterilization Autoclave at 121°C at 1 bar for 20 minutes/EO/Gamma

Ordering Information
Item Code Pore Size(μm) Diameter(mm) Sterile Quantity/pk
WNY1322N 0.22 13 No 100pcs
WNY1345N 0.45 13 No 100pcs
WNY2522N 0.22 25 No 100pcs
WNY2545N 0.45 25 No 100pcs

3. Sterile Nylon Syringe Filters
Hawach sterile nylon syringe filters autoclave at 121°C at 1 bar for 20 minutes/EO/Gamma. The nylon syringe filters diameter range 4mm, 13mm, 25mm, 33mm, 50mm. Pore size: 0.1μm, 0.22μm, 0.45μm, 0.65μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm

Description of Sterile Nylon Syringe Filters

Sterile hydrophilic nylon membrane are widely used in various analysis processes. The Nylon syringe filter for HPLC is characterized by large flux, low dissolution. The good physical properties of nylon can meet the analysis needs of various test conditions. Hydrophilicity, high protein binding, and high dirt holding capacity are the natural characteristics of nylon.

Features

•The γ-ray sterilized nylon syringe filter is individually packaged and does not contain any heat source, DNA
•No need to infiltrate before use
•Uniform pore size
Applications of Sterile Hydrophilic Syringe Filter
•Filtration of various solvents and liquid chemicals
•Samples containing low solid content-filtration will improve column life
•0.22 μm nylon syringe filter can be used in biological samples
•Photoresist in the electronic semiconductor industry, filtration of production water
Technical Data
Filter Media Sterile Nylon
Pore Size, μm 0.1μm, 0.22μm, 0.45μm, 0.65μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm
Diameter 4mm 13mm 25mm 33mm 50mm
Housing Medical PP Medical PP Medical PP Medical PP Medical PP
Filtration Area 0.2cm2 1.3cm2 4.9cm2 8.5cm2 19.8cm2
Maximum Pressure 5.2bar 5.2bar 5.2bar 5.2bar 5.2bar
Process Volume 2mL 10mL 100mL 200mL 5000mL
Hold-up Volume < 10μL < 50μL < 100μL < 200μL < 350μL
Inlet Female Luer Lock Female Luer Lock Female Luer Lock Female Luer Lock  Both inlet and outlet is 7-13mm stepped hose barb connection with 6:100 Luer slip
Outlet Male luer slip Male luer slip Male luer slip Male luer slip
Flow Direction Flow should enter from the inlet Both is fine
Maximum Operating Temperature 60°C
Sterilization Gamma Irradiation
Endotoxin ≦0.25 EU/ML

Ordering Information
Item Code Pore Size(μm) Diameter(mm) Sterile Pre-filter Quantity/pk
SLNY1322S 0.22 13 Yes No 100pcs
SLNY1345S 0.45 13 Yes No 100pcs
SLNY1322SP 0.22 13 Yes PP 100pcs
SLNY1345SP 0.45 13 Yes PP 100pcs
SLNY1322SG 0.22 13 No GF 100pcs
SLNY1345SG 0.45 13 No GF 100pcs
SLNY2522S 0.22 25 Yes No 100pcs
SLNY2545S 0.45 25 Yes No 100pcs
SLNY2522SP 0.22 25 Yes PP 100pcs
SLNY2545SP 0.45 25 Yes PP 100pcs
SLNY2522SG 0.22 25 No GF 100pcs
SLNY2545SG 0.45 25 No GF 100pcs
Download All Ordering Information