0.1 um CA syringe filters
0.22 um CA syringe filters
0.45 um CA syringe filters
CA syringe filters
0.22 CA sterile Syringe Filter for HPLC
0.45 CA sterile Syringe Filter for HPLC
CA sterile Syringe Filters

Cellulose Acetate Syringe Filter

Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm
Housing: Medical PP
Availability: In Stock


Select:  CA Syringe Filter,  Sterile CA Syringe Filter

Cellulose acetate syringe filters are hydrophilic membrane filters designed for laboratory filtration of aqueous and biological samples. They are widely used for sample clarification and sterile filtration due to their low protein binding and consistent filtration performance.


What Are Cellulose Acetate Syringe Filters?

A cellulose acetate (CA) syringe filter consists of a medical-grade polypropylene housing combined with a hydrophilic cellulose acetate membrane. As liquid is pushed through the filter using a syringe, particles and contaminants larger than the membrane pore size are retained, producing a clean and consistent filtrate.

Because of their low protein adsorption characteristics, CA syringe filters are commonly selected for biological, clinical, and analytical laboratory applications.


Key Features

  • Hydrophilic Cellulose Acetate Membrane: Suitable for direct filtration of aqueous solutions.
  • Low Protein Binding: Minimizes sample loss and preserves sensitive biomolecules.
  • Multiple Pore Sizes: 0.1 μm, 0.22 μm, 0.45 μm, 0.8 μm, 1.0 μm, 3.0 μm, and 5.0 μm options.
  • Various Diameters: Available in 4 mm, 13 mm, 25 mm, 33 mm, and 50 mm.
  • Sterile and Non-Sterile Versions: Compatible with a wide range of laboratory workflows.
  • Standard Luer Connections: Compatible with common laboratory syringes.

Applications

  • Biological sample preparation and clarification
  • Aqueous solution filtration
  • HPLC and analytical sample pretreatment
  • Environmental and water sample filtration
  • Clinical and biochemical laboratory workflows

Technical Specifications

Parameter Specification
Membrane Material Cellulose Acetate (Hydrophilic)
Pore Size Range 0.1 μm – 5.0 μm
Diameter Options 4 mm – 50 mm
Housing Material Medical-grade Polypropylene (PP)
Recommended Sample Volume 2 mL – 5000 mL

Frequently Asked Questions

What are cellulose acetate syringe filters used for?

They are used to clarify and sterile-filter aqueous and biological liquid samples in laboratory environments, especially when low protein binding is required.

Why choose cellulose acetate over other membrane materials?

Cellulose acetate membranes are hydrophilic and exhibit low protein adsorption, helping preserve sensitive biomolecules and improve sample recovery.

Which pore size should I select?

A 0.22 μm pore size is commonly used for sterile filtration, while 0.45 μm is suitable for general particulate removal. Final selection should be based on application requirements.

Are these syringe filters sterile?

Both sterile and non-sterile cellulose acetate syringe filter options are available depending on laboratory needs.


Request Specifications and Pricing

If you are looking for reliable cellulose acetate syringe filters for laboratory use, please contact us to request detailed specifications, pricing information, and technical support.


Hawach Series CA Syringe Filter

Technical Data of Hawach Series CA Membrane Syringe Filter
Filter Media Cellulose Acetate
Diameter 4mm 13mm 25mm 33mm 50mm
Housing Medical PP Medical PP Medical PP Medical PP Medical PP
Pore Size 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm
Filtration Area 0.2cm2 1.3cm2 4.9cm2 8.5cm2 19.8cm2
Maximum Pressure 5.2bar 5.2bar 5.2bar 5.2bar 5.2bar
Process Volume 2mL 10mL 100mL 200mL 5000mL
Pre-filter 1μm GF or PP 1μm GF or PP 1μm GF or PP 1μm GF or PP 1μm GF or PP
Hold-up Volume < 10μL < 50μL < 100μL < 200μL < 350μL
Inlet Female Luer Lock Female Luer Lock Female Luer Lock Female Luer Lock Stepped barb
Outlet Male luer slip Male luer slip Male luer slip Male luer slip Stepped barb
Operate temperature 60°C

Ordering Information
Item Code Pore Size(μm) Diameter(mm) Sterile Pre-filter Quantity/pk
SLCA1322N 0.22 13 No No 100pcs
SLCA1345N 0.45 13 No No 100pcs
SLCA1322NP 0.22 13 No PP 100pcs
SLCA1345NP 0.45 13 No PP 100pcs
SLCA1322NG 0.22 13 No GF 100pcs
SLCA1345NG 0.45 13 No GF 100pcs
SLCA2522N 0.22 25 No No 100pcs
SLCA2545N 0.45 25 No No 100pcs
SLCA2522NP 0.22 25 No PP 100pcs
SLCA2545NP 0.45 25 No PP 100pcs
SLCA2522NG 0.22 25 No GF 100pcs
SLCA2545NG 0.45 25 No GF 100pcs
Download All Ordering Information

Sterile CA Syringe Filter


Technical Data
Filter Media Sterile Cellulose Acetate
Pore Size 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0um, 3.0μm, 5.0μm
Diameter 4mm 13mm 25mm 33mm 50mm
Housing Medical PP Medical PP Medical PP Medical PP Medical PP
Filtration Area 0.2cm2 1.3cm2 4.9cm2 8.5cm2 19.8cm2
Maximum Pressure 5.2bar 5.2bar 5.2bar 5.2bar 5.2bar
Process Volume 2mL 10mL 100mL 200mL 5000mL
Hold-up Volume < 10μL < 50μL < 100μL < 200μL < 350μL
Inlet Female Luer Lock Female Luer Lock Female Luer Lock Female Luer Lock Both inlet and outlet is 7-13mm stepped hose barb connection with 6:100 Luer slip
Outlet Male luer slip Male luer slip Male luer slip Male luer slip
Flow Direction Flow should enter from the inlet Both is fine
Maximum Operating Temperature 60°C
Sterilization Gamma Irradiation
Endotoxin ≦0.25 EU/ML
Ordering Information
Item Code Pore Size(μm) Diameter(mm) Sterile Pre-filter Quantity/pk
SLCA1322S 0.22 13 Yes No 100pcs
SLCA1345S 0.45 13 Yes No 100pcs
SLCA1322SP 0.22 13 Yes PP 100pcs
SLCA1345SP 0.45 13 Yes PP 100pcs
SLCA1322SG 0.22 13 Yes GF 100pcs
SLCA1345SG 0.45 13 Yes GF 100pcs
SLCA2522S 0.22 25 Yes No 100pcs
SLCA2545S 0.45 25 Yes No 100pcs
SLCA2522SP 0.22 25 Yes PP 100pcs
SLCA2545SP 0.45 25 Yes PP 100pcs
SLCA2522SG 0.22 25 Yes GF 100pcs
SLCA2545SG 0.45 25 Yes GF 100pcs